CLQRK - D5S-6, DEOXIT D5 SPRAY, 200 ML

  • MSDS: CLQRK
  • Manufacturer: CAIG LABORATORIES INC
  • Product Name: D5S-6, DEOXIT D5 SPRAY, 200 ML
  • National Stock Number: 6850-01-435-6476
Product Identification

Product ID:D5S-6, DEOXIT D5 SPRAY, 200 ML
MSDS Date:07/08/2001
FSC:6850
NIIN:01-435-6476
Status Code:A
MSDS Number: CLQRK

Responsible Party
CAIG LABORATORIES INC
12200 THATCHER CT
POWAY, CA 92064
US

Emergency Phone: (800)424-9300

Info Phone: 858-486-8388

Preparer: MARK K. LOHKEMPER

Cage: 55403

Contractor
CAIG LABORATORIES INC
POWAY, CA 92064 US

Telephone: 858-486-8388

Cage: 55403

Ingredients

PETROLEUM NAPHTHA

CAS: 64742-88-7

OSHA PEL 100 PPM

ACGIH TLV: 100 PPM


ISOBUTANE/PROPANE 75-28-5/74-98-6

OSHA PEL 800 PPM

ACGIH TLV: 1000 PPM


DEOXIT (NON-HAZARDOUS)

OSHA PEL NOT PROVIDED

ACGIH TLV: NOT PROVIDED

Hazards

LD50 LC50 Mixture:NOT PROVIDED
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:SKIN CONTACT: REPEATED OR PROLONGED
CONTACT MAY CAUSE DRYNESS OF SKIN. WASH WITH SOAP AND WATER AND
APPLY HAND CREAM. EYE CONTACT: CONTACT WITH LIQUIDS, MISTS OR
VAPORS CAN CAUSE ACUTE EYE IRRITATION. INGESTION: HARMFUL IF
SWALLOWED. MAY CAUSE ACUTE IRRITATION OF THE LININGS OF THE MOUTH,
THROAT AND NOSE. VOMITING MAY RESULT, CAUSING ASPIRATION INTO THE
LUNGS CAUSING CHRONIC PULMONARY EDEMA, CHEMI CAL PNEUMONIA.
INHALATION: HARMFUL IF PRODUCT VAPORS INHAED IN HIGH
CONCENTRATIONS. MAY CAUSE IRRITATION OF LUNGS FOLLOWED BY CHRONIC
PULMONARY EDEMA. ACUTE IRRITATION OF MOUTH AND NASAL PASSSAGES MAY
RESULT FROM OVEREXPOSURE.
Explanation of Carcinogenicity:NONE OF THE COMPONENTS OF THIS PRODUCT
ARE KNOWN TO HAVE CARCINOGENIC, MUTAGENIC TERATOGENIC,
SENSITIZATION EFFECTS.
Effects of Overexposure:SKIN CONTACT: REPEATED OR PROLONGED CONTACT MAY
CAUSE DRYNESS OF SKIN. EYE CONTACT: CONTACT WITH LIQUIDS, MISTS OR
VAPORS CAN CAUSE ACUTE EYE IRRITATION. INGESTION: MAY CAUSE ACUTE
IRRITATION OF THE L ININGS OF THE MOUTH, THROAT AND NOSE. VOMITING
MAY RESULT.. INHALATION: HARMFUL IF PRODUCT VAPORS INHAED IN HIGH
CONCENTRATIONS. MAY CAUSE IRRITATION OF LUNGS.
Medical Cond Aggravated by Exposure:NOT PROVIDED

First Aid

First Aid:SKIN CONTACT: WASH WITH SOAP AND WATER. SEEK MEDICAL
ATTENTION IF IRRITATION PERSISTS. EYE CONTACT: IMMEDIATELY FLUSH
WITH PLENTY OF WATER. REMOVE ANY CONTACT LENSES AND CONTINUE
FLUSHING FOR AT LEAST 15 MINUTES. SEEK MEDICAL ATTENTION IF
IRRITATION DEVELOPS OR PERSISTS. INGESTION: SEEK MEDICAL ATTENTION
IMMEDIATELY. INDUCE VOMITING ONLY AS DIRECTED BY MEDICAL PERSONNEL.
INHALATION: REMOVE TO FRES H AIR. IF NOT BREATHING, GIVE ARTIFICIAL
RESPIRATION. IF BREATHING IS DIFFICULT, GIVE OXYGEN. SEEK MEDICAL
ATTENTION.

Fire Fighting

Flash Point:<43.3C, 110.F
Lower Limits:1.0
Upper Limits:6.0
Extinguishing Media:ALCOHOL FOAM , WATER FOG, DRY CHEMICAL OR CO2 .
NOT TO BE USED: WATER.
Fire Fighting Procedures:AS IN ANY FIRE, WEAR SELF-CONTAINED BREATHING
APPRATUS AND FULL PROTECTIVE GEAR.
Unusual Fire/Explosion Hazard:NOT PROVIDED

Accidental Release

Spill Release Procedures:OBSERVE RECOMMENDATION FOR PERSONAL PROTECTION
DETAILED IN CONTROL MEASURES SECTION. ABSORB WITH INERT MATERIAL
SUCH AS SAND, CLAY, OR DIRT AND PLACE IN SEALED METAL CONTAINER FOR
DISPOSAL. SINCE PROD UCTS ARE NOT NORMALLY USED IN LARGE QUANTITIES
AND PRODUCT IS NON-HAZARDOUS, ABSORB WITH INERT MATERIAL AND
DISCARD AS YOU WOULD MINERAL OIL. AVOID RUNOFF INTO SEWERS AND
DITCHES THAT LEAD TO WATERWAY
Neutralizing Agent:NOT RELEVANT

Handling

Handling and Storage Precautions:STORE IN A COOL, DRY PLACE, AWAY FROM
HEAT, SPARKS OR FLAMES. KEEP CONTAINER TIGHTLY CLOSED WHEN NOT IN
USE. DO NOT STORE IN DIRECT SUNLIGHT. KEEP OUT OF REACH OF
CHILDREN. AVOID ACTIVITIES THAT COULD CAUSE SPLASHING OF THE
SPILLED MATERIAL OR CREATE MISTS.
Other Precautions:AVOID PROLONGED OR REPEATED CONTACT WITH SKIN, EYES
OR CLOTHING. AVOID BREATHING PRODUCT VAPOR FOR EXTENDED PERIODS OF
TIME. USE ONLY WITH ADEQUATE VENTILATION. GENERAL VENTILATION
SHOULD BE ADEQUATE, BUT USE LOCAL EXHAUST VENTILATION IN CONFINED
SPACES OR AT POINTS OF EXCESSIVE DISCHARGE.

Exposure Controls

Respiratory Protection:FULL-FACE RESPIRATOR MASK EQUIPPED WITH ACID
GAS/ ORGANIC VAPOR CARTRIDGE OR FUME HOOD OR OTHER TYPE OF LOCAL
EXHAUST VENTILATION.
Ventilation:GENERAL VENTILATION SHOULD BE SUFFICIENT TO CONTROL
AIRBORNE VAPOR LEVELS. LOCAL EXHAUST VENTILATION SHOULD BE USED IF
LARGE AMOUNTS ARE RELEASED.
Protective Gloves:WEAR CHEMICAL RESISTANT RUBBER GLOVES WITH REPEATED
EXPOSURE.
Eye Protection:WEAR SAFETY GLASSES/CHEMICAL SPLASH GOGGLES OR FULL FACE
SHIELD.
Other Protective Equipment:NONE REQUIRED FOR NORMAL CONDITIONS OF
INDUSTRIAL USE.
Work Hygienic Practices:WASH HANDS BEFORE EATING OR SMOKING WHEN USING
THIS PRODUCT.
Supplemental Safety and Health
ABBREVIATION: N/A = NOT APPLICABLE. N/AV = NOT AVAILABLE. N/K =
UNKNOWN. N/P = NOT PROVIDED. N/R = NOT RELEVANT. N/D = NOT
DETERMINED. N/E = NOT ESTABLISHED.

Chemical Properties

HCC:V3
NRC/State Lic Num:NOT RELEVANT
Boiling Pt:=160.C, 320.F
Melt/Freeze Pt:M.P/F.P Text:NOT AVAILABLE
Decomp Temp:Decomp Text:NOT PROVIDED
Vapor Pres:<12 @ 38C
Vapor Density:N/AV
Volatile Org Content %:95
Viscosity:1 (WATER=1)
Evaporation Rate & Reference:NOT PROVIDED
Solubility in Water:NOT PROVIDED
Appearance and Odor:LIGHT RED LIQUID IN AEROSOL; ETHERAL/HYDROCARBON
ODOR.
Percent Volatiles by Volume:NOT PROVIDED
Corrosion Rate:NOT PROVIDED

Stability

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS.
Stability Condition to Avoid:DO NOT SPRAY AROUND HIGH HEAT, OPEN
FLAMES, HOT METAL SURFACES.
Hazardous Decomposition Products:OXIDES OF CARBON AND UNBURNED
HYDROCARBONS.
Conditions to Avoid Polymerization:HAZARDOUS EXOTHERMIC POLYMERIZATION
WILL NOT OCCUR. NOT SENSITIVE TO PRESSURE, LIGHT OR SHOCK. WILL NOT
REACT WITH WATER.

Disposal

Waste Disposal Methods:PACKAGE, TRANSPORT AND DISPOSE OF IN ACCORDANCE
WITH ALL LOCAL, STATE AND FEDERAL REGULATIONS. PRODUCT WASTE IS
SUITABLE FOR FUELS BLENDING FOR ENERGY RECOVERY OR DISPOSAL BY
INCINERATION. PRODUCT MAY BE RECOVERABLE BY DISTILLATION OR
RECYCLING. LANDFILING IS NOT RECOMMENDED FOR DISPOSAL.

Toxicology

Toxicological Information:NONE OF THE COMPONENTS OF THIS PRODUCT ARE
KNOWN TO HAVE CARCINOGENIC, MUTAGENIC TERATOGENIC, SENSITIZATION
EFFECTS. BREATHING HIGH VAPOR CONCENTRATIONS FOR LONG PERIODS OF
TIME MAY LEAD TO NARCOSIS.

Other Information

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.

Ecology

Ecological:MOBILITY: NO PRODUCT-SPECIFIC DATA IS AVAILABLE. PERSISTENCE
AND DEGRADABILITY: NO PRODUCT-SPECIFIC DATA AVAILABLE.
BIOACCUMULATIVE POTENTIAL: NO PRODUCT-SPECIFIC DATA AVAILABLE.
AQUATIC TOXICITY: NO PRODUCT-SPECIFIC DATA IS AVAILABLE. OTHER
DATA PERTAINING TO ECOTOXICITY: IN LARGE QUANTITIES, WATER RUNOFF
MAY CAUSE ENVIRONMENTAL DAMAGE.

Transport

Transport Information:DOT - SHIPPING NAME: CONSUMER PRODUCT. CLASS:
ORM-D. UN NO.: NOT REQUIRED. IMDG -SHIPPING NAME: AEROSOL PRODUCTS.
CLASS: 2. UN NO.: 1950. IMDG CODE: PAGE 2102. LABEL: NOT REQUIRED.
IATA -UN NO.: ID-80 00. CLASS OR DIVISION: 9. LABEL: CONSUMER
COMMODITY ORM-D. SUBSIDIARY RISK: NONE. PACKAGING INSTRUCTIONS:
910. MARINE POLLUTANT: NO.

Regulatory

SARA Title III Information:NOT PROVIDED
Federal Regulatory Information:ALL INGREDIENTS ARE LISTED ON THE TSCA
INVENTORY. OSHA HAZARDOUS COMPONENTS (29CFR1910.1200) PETROLEUM
NAPHTHA, 100PPM (PEL/TWA), 100PPM(TLV/TWA). ISOBUTANE/PROPANE,
800PPM/1000PPM (ACGIH-TLV)
State Regulatory Information:CALIFORNIA PROPOSITION 65: THE CALIFORNIA
LIST OF CHEMICALS, "KNOWN TO CAUSE CANCER OR REPRODUCTIVE TOXICITY"
IS SO EXTENSIVE IT REQUIRES MORE CLARIFICATION, RESEARCH AND
EVALUATION. MEANWHILE, ALL CH EMICALS DISTRIBUTED BY, OR
MANUFACTURED BY CAIG LABORATORIES, SHALL BE ASSUMED TO BE ON THE
LIST OR CONTAIN DETECTABLE AMOUNTS OF CHEMICAL LISTED.